Vaillant ecoTEC 937 needing regular resets: F.62 and F.75, new PCB and pressure sensor
The last ten faults in the history were F.62 and F.75. Repaired and given a full strip-down service on one visit.
Genuine completed jobs from Synergy Gas & Plumbing — real faults, real diagnoses, real outcomes. No stock photography, no invented reviews. Where a job has a full write-up with the engineer's photos, the ticket links to it on synergygas.org.
The last ten faults in the history were F.62 and F.75. Repaired and given a full strip-down service on one visit.
A rental with no heating or hot water. Fixed on one visit, and the landlord and tenant were extremely happy.
No heating or hot water at a restaurant. Both parts fitted the same day, before opening time.
The boiler kept going off, and the customer had to keep topping up the pressure. Booked as a breakdown and a service.
Booked in for a service, the boiler was found not working. Fixed the day before the customer went on a cruise.
The customer had been bleeding radiators to bring the pressure down, and expected to be told they needed a new boiler.
An evening call. The boiler was locked out on C7, a fan fault, and an H09 code had been coming back for months.
A rental where we had already replaced a sludged diverter valve and plate heat exchanger. The landlord replaced the part without flushing the system, and the hot water failed again nine days later.
An out-of-hours call on a Sunday. The boiler was showing E133 and there was no heating or hot water.
We were there for the annual service, and the customer mentioned the boiler was leaking and the heating was staying on with nothing asking for it.
An out-of-hours call on a Saturday. The overheat light was flashing when we arrived.
The customer's boiler was showing an H09 fault on its display.
A customer called after 10pm with water leaking. We were on site within 30 minutes. They expected the water to be turned off at the stop tap and a return visit.
A customer in a Newtown apartment block on a heat network had no hot water and leaks from their Meibes heat interface unit. Five different engineers had already been out to try to diagnose it.
Not every no-hot-water call is the boiler. A tenant in a city centre flat had no hot water from an electrically heated Heatrae Sadia Megaflo and asked us to replace both immersion elements.
Existing customers smelt gas in their upstairs bathroom and called the gas emergency line. Cadent found a 20 mbar pressure drop on the internal pipework and capped the supply at the meter, which left the boiler off. They rang us and we attended the same day.
The boiler had locked out on E118, Main and Baxi's low-pressure code. The customer could not top it up because the filling loop had been boxed in with the pipework. Once the pressure was back, the heating still would not come on: the wireless room thermostat had a blank screen.
The tenant had heating but no hot water, and the boiler showed Er 14, the Advance range's circulation code. With the case off, the diverter valve was jammed with black magnetite sludge and the plate heat exchanger behind it was choked with the same.
The customer had been told by previous engineers that the boiler was finished. It kept locking out on ignition. With the burner out, the burner gasket had perished and the electrode was damaged.
Booked online as a repair. The control panel was hanging down, held with tape and a piece of copper pipe. A snapped hinge clip, a common failure on the Compact, and not a reason to replace the boiler.
A returning customer with no hot water and EA showing. After the safety checks the fault traced to the gas valve, which is not a van-stock part on this model.
The tenant reported a boiler locking out on overheat. The system pump was found burnt out, choked with the sludge that had been circulating for years.
Water inside the boiler case. The right-hand hydraulic manifold had corroded and was weeping at the joints, and the part is not one we carry.
Another engineer had noted a leak on the landlord's safety check. On the follow-up we traced it to the condensate collector inside the combustion box, whose seals had perished.
Rust at the back of the heat exchanger and a CO reading on the analyser, in a house with a young family. Made safe on the spot, then repaired with the landlord's go-ahead.
The customer's Ariston Evo combi boiler had stopped producing hot water — every time a hot tap was opened, the boiler overheated instead. A fault like this can look like several different things before it's properly diagnosed.
The customer had no hot water at all from their Gledhill Pulsacoil electric boiler — a less common system that a lot of general boiler repair companies aren't set up to work on.
The customer's existing boiler broke down and needed replacing as an emergency, rather than a planned installation.
The customer reported a suspected gas leak, with the source not visible or accessible from above the floor.